- Product Name
Aluminum and Steel Structures and Shelters
- Manufacturer
AustinMohawk and Company, Inc.
2175 Beechgrove Place
Utica, NY 13501
(800) 765-3110
(315) 793-9390
Fax (315) 793-9370
Email: info@austinmohawk.com
Web: www.austinmohawk.com
- Product Description
BASIC USE
AustinMohawk and Company, Inc. manufactures portable
and mobile buildings, including prefabricated aluminum
and steel buildings and shelters. These buildings
are typically used as guard booths, cashier and
attendant booths, petroleum kiosks, access control
buildings, utility buildings, smoking shelters,
transit shelters, waiting shelters, equipment shelters,
and vestibules. Custom fabricated buildings for
special purposes, including bullet resistance, are
available.
COMPOSITION & MATERIALS
Aluminum Buildings
Structural framing is 6036-T6 aluminum alloy extrusions.
Connections are fastened internally to framing systems
using mechanical fasteners or are MIG welded. Base
structure is a layered assembly, 2" (50.8 mm)
thick, consisting of a .032" (0.81 mm) mill
finish aluminum underside, plywood, expanded polystyrene
insulation and a finished floor of nonskid tread
plate. Units 6' x 6' (1829 x 1829 mm) or larger
are mounted on a 4" (101.6 mm) steel channel
base frame with anchoring angles. Lower exterior
wall panel is .032" (0.81 mm) aluminum, 3"
(76.2 mm) insulation and .032" (0.81 mm) interior
aluminum. Overall thickness of panel is 3"
(76.2 mm). Interior ceiling is foam core panel system
constructed from 24 ga prefinished white with expanded
polystyrene core.
Roof is constructed using 20 ga, G-90 galvanized
interlocking pan sections. Sections are factory
coated with industrial quality polyester white paint.
Sections are 3" (76.2 mm) high with varying
widths able to support minimum of 50 psf (244 kg/m3)
live load. Roof drains into a full perimeter gutter
system. Fixed windows are single pane 1/8"
(3.2 mm) tempered safety glass and locks. Glass
is glazed within wall system extrusions and not
fastened to exterior wall. Sliding doors are extruded
aluminum frame, top hung type using heavy duty ball
bearing nylon tire with steel hub and solid brass
cylinder lock. Optional is a commercial grade swing
door and lock set.
Steel Buildings
Customer length and width, 96" (2438.4 mm)
in height. Framing is 2" x 2" (50.8 x
50.8 mm) x 0.120" (3 mm) structural tube, ASTM
A500 grade B, seams MIG welded. Base/Floor of building
is typically constructed on a 4" (101.6 mm)
galvanized structural tube frame. Floor assembly
is 2" (50.8 mm) thick comprised of galvanized
steel under-side, insulation and 1/8" (3.2
mm) aluminum treadplate finished floor. Wall panels
are 14 ga exterior, galvanized, MIG welded into
place, 2" (50.8 mm) R-16 insulation, and a
16 ga inside face. Interior ceiling is a foam core
panel system constructed from 24 ga prefinished
white with expanded polystyrene core.
Roof construction is 20 ga, G-90 interlocking pan
sectors. Sections are factory coated with industrial
quality polyester white paint. Sections are 3"
(76.2 mm) high with varying widths able to support
minimum of 50 psf (244 kg/m3) live load, draining
into a full perimeter gutter system. Exterior surfaces
are smooth and flat and painted using an epoxy/urethane
paint system designed to withstand salt spray and
freeze/thaw. Fixed windows are 3/16" (4.8 mm)
tempered safety glass. Sliding and cashier windows
are 1/8" (3.2 mm) tempered safety glass. Window
frames are anodized aluminum and fastened to building
with no exposed fasteners. Moving windows are supplied
with locking device. Standard doors are sliding
type, top hung style using an aluminum overhead
track and rollers. Swing door is commercial grade
aluminum with 3 hinges and closure arm. Both style
doors are supplied with morose locks and removable
cylinders.
Aluminum Shelters
Custom length and width, 86" (2184.4 mm) exterior
height and 82" (2082.8 mm) interior ceiling
height. Frame is 6063-T6 aluminum alloy extrusions
assembled using internally located mechanical fasteners.
Roof construction is 20 ga steel, G-90 galvanized
steel interlocking pan sections factory coated with
industrial quality polyester white paint. Sections
are 3" (76.2 mm) high with varying widths able
to support minimum of 50 psf (244 kg/m3) live load.
Roof drains into a full perimeter gutter system
and drains by scupper in rear of shelter. Interior
ceiling is a foam core panel system constructed
from 24 ga prefinished white with expanded polystyrene
core and able to support optional lighting or heat
panels. Fixed windows are single pane _" (6.4
mm) minimum clear tempered safety glass. Glass is
framed to shelter using concealed fastener aluminum
sash system, glass stop is self locking aluminum
with built-in gasketing.
Aluminum & Steel Shelters
Options
Glazing:
_" (6.4 mm) tempered safety glass, 0.1875"
or 0.220" (4.8 or 5.6 mm) polycarbonate,
tinting, in gray or bronze.
Lighting:
Twin bulb fluorescent fixtures.
Venting:
Switch operated wall fans.
Benches:
6' (1828.8 mm), 8' (2438.4 mm) end 10' (3048 mm)
pedestal mounted polyvinyl chloride (PVC) coated
heavy duty steel. Installed directly to concrete
pad with expansion anchors.
TYPES
Building standard style options include classic
square corner, soft corner, “easy round"
and “tru-view.”
COLORS
Quaker Bronze is standard. Rawhide, Slate Gray,
Ascot White, Black, Forest Green available upon
request.
ELECTRICAL
Electrical wiring is done according to National
Electrical Code (NEC) Standards. Load center is
a General Electric 125 Amp 120/240 volt unit with
4 to 8 open circuits. Wiring is within surface mounted
electrical metallic conduit (EMT) and a ground-fault
circuit-interrupter (GFCI) duplex receptacle with
tester is provided. Lighting is twin fluorescent
light with tube cover. Heating is wall mounted electric
with fan forced operation, 1500w/5120 BTU and thermostat
in an enamel coated 20 ga steel cabinet.
- Technical Data
APPLICABLE STANDARDS
American Society for Testing & Materials (ASTM)
– ASTM A500 – Standard Specification
for Cold-Formed Welded and Seamless Carbon Steel
Structural Tubing in Rounds and Shapes
APPROVALS
Consult AustinMohawk and Company, Inc.
PHYSICAL/CHEMICAL PROPERTIES
Test reports are available upon request.
FIRE RATING
Fire resistance performance varies depending on
construction type and options. Consult AustinMohawk
and Company, Inc.
SOUND RATING
Consult AustinMohawk and Company, Inc. for acoustical
performance.
- Installation
PREPARATORY WORK
Handle and store product according to AustinMohawk
and Company, Inc. recommendations. Protect building
and accessory components until ready for installation.
It is recommended shop drawings be prepared showing
layout, profiles and all product component, including
anchorage, accessories, finish colors, patterns
and textures. Verify that substrate conditions which
have been previously installed by other contractors
are acceptable for product installation in accordance
with manufacturer's instructions.
METHODS
Install building structure true to line, level,
plumb, rigid, and secure. Level base plates to true
plane with full bearing to support structure, set
in-place with anchor bolts as recommended by building
manufacturer.
Aluminum Shelter Anchoring
Install shelter on concrete pad 4" (101.6 mm)
minimum thickness and 12" (304.8 mm) minimum
larger than shelter in both length and width. Anchor
shelter to pad using aluminum “boots”
and factory supplied expansion anchors.
Steel Shelter Anchoring
Install shelter on concrete pad 6" (152.4 mm)
thickness and 18" (457.2 mm) minimum larger
than shelter in both length and width. Anchor shelter
to pad using height adjustable steel base plates
and _" (12.7 mm) minimum expansion anchors.
Cleaning
Remove temporary coverings and protection of adjacent
work areas. Repair or replace damaged installed
products. Clean installed products in accordance
with manufacturer's instructions prior to owner's
acceptance. Remove construction debris from site.
Complete installation recommendations are available
from the manufacturer.
PRECAUTIONS
Protect installed product and finish surfaces from
damage during construction.
BUILDING CODES
Current data on building code requirements and product
compliance can be obtained from AustinMohawk and
Company, Inc.'s technical support specialists. Installation
must comply with the requirements of all applicable
local, state and national code jurisdictions.
- Availability & Cost
AVAILABILITY
These buildings are available throughout North America.
Contact manufacturer for information on lead times.
COST
Product and installation cost information can be
obtained from AustinMohawk and Company, Inc.
- Warranty
Contact manufacturer.
- Maintenance
Contact manufacturer.
- Technical Services
Service personnel offer design assistance and technical
support. Structures are accompanied by a trained
representative to advise on unloading and installation
procedures. For technical assistance, contact AustinMohawk
and Company, Inc.
- Filing Systems
- Architects' First Source for Product
- MANU-SPEC®
- Sweet's Catalog Files
- Additional product information