  1. Product Name
    Aluminum and Steel Structures and Shelters

  2. Manufacturer
    AustinMohawk and Company, Inc.
    2175 Beechgrove Place
    Utica, NY 13501
    (800) 765-3110
    (315) 793-9390
    Fax (315) 793-9370
    Email: info@austinmohawk.com
    Web: www.austinmohawk.com

  3. Product Description
    BASIC USE
    AustinMohawk and Company, Inc. manufactures portable and mobile buildings, including prefabricated aluminum and steel buildings and shelters. These buildings are typically used as guard booths, cashier and attendant booths, petroleum kiosks, access control buildings, utility buildings, smoking shelters, transit shelters, waiting shelters, equipment shelters, and vestibules. Custom fabricated buildings for special purposes, including bullet resistance, are available.

    COMPOSITION & MATERIALS
    Aluminum Buildings
    Structural framing is 6036-T6 aluminum alloy extrusions. Connections are fastened internally to framing systems using mechanical fasteners or are MIG welded. Base structure is a layered assembly, 2" (50.8 mm) thick, consisting of a .032" (0.81 mm) mill finish aluminum underside, plywood, expanded polystyrene insulation and a finished floor of nonskid tread plate. Units 6' x 6' (1829 x 1829 mm) or larger are mounted on a 4" (101.6 mm) steel channel base frame with anchoring angles. Lower exterior wall panel is .032" (0.81 mm) aluminum, 3" (76.2 mm) insulation and .032" (0.81 mm) interior aluminum. Overall thickness of panel is 3" (76.2 mm). Interior ceiling is foam core panel system constructed from 24 ga prefinished white with expanded polystyrene core.

    Roof is constructed using 20 ga, G-90 galvanized interlocking pan sections. Sections are factory coated with industrial quality polyester white paint. Sections are 3" (76.2 mm) high with varying widths able to support minimum of 50 psf (244 kg/m3) live load. Roof drains into a full perimeter gutter system. Fixed windows are single pane 1/8" (3.2 mm) tempered safety glass and locks. Glass is glazed within wall system extrusions and not fastened to exterior wall. Sliding doors are extruded aluminum frame, top hung type using heavy duty ball bearing nylon tire with steel hub and solid brass cylinder lock. Optional is a commercial grade swing door and lock set.

    Steel Buildings
    Customer length and width, 96" (2438.4 mm) in height. Framing is 2" x 2" (50.8 x 50.8 mm) x 0.120" (3 mm) structural tube, ASTM A500 grade B, seams MIG welded. Base/Floor of building is typically constructed on a 4" (101.6 mm) galvanized structural tube frame. Floor assembly is 2" (50.8 mm) thick comprised of galvanized steel under-side, insulation and 1/8" (3.2 mm) aluminum treadplate finished floor. Wall panels are 14 ga exterior, galvanized, MIG welded into place, 2" (50.8 mm) R-16 insulation, and a 16 ga inside face. Interior ceiling is a foam core panel system constructed from 24 ga prefinished white with expanded polystyrene core.

    Roof construction is 20 ga, G-90 interlocking pan sectors. Sections are factory coated with industrial quality polyester white paint. Sections are 3" (76.2 mm) high with varying widths able to support minimum of 50 psf (244 kg/m3) live load, draining into a full perimeter gutter system. Exterior surfaces are smooth and flat and painted using an epoxy/urethane paint system designed to withstand salt spray and freeze/thaw. Fixed windows are 3/16" (4.8 mm) tempered safety glass. Sliding and cashier windows are 1/8" (3.2 mm) tempered safety glass. Window frames are anodized aluminum and fastened to building with no exposed fasteners. Moving windows are supplied with locking device. Standard doors are sliding type, top hung style using an aluminum overhead track and rollers. Swing door is commercial grade aluminum with 3 hinges and closure arm. Both style doors are supplied with morose locks and removable cylinders.

    Aluminum Shelters
    Custom length and width, 86" (2184.4 mm) exterior height and 82" (2082.8 mm) interior ceiling height. Frame is 6063-T6 aluminum alloy extrusions assembled using internally located mechanical fasteners. Roof construction is 20 ga steel, G-90 galvanized steel interlocking pan sections factory coated with industrial quality polyester white paint. Sections are 3" (76.2 mm) high with varying widths able to support minimum of 50 psf (244 kg/m3) live load. Roof drains into a full perimeter gutter system and drains by scupper in rear of shelter. Interior ceiling is a foam core panel system constructed from 24 ga prefinished white with expanded polystyrene core and able to support optional lighting or heat panels. Fixed windows are single pane _" (6.4 mm) minimum clear tempered safety glass. Glass is framed to shelter using concealed fastener aluminum sash system, glass stop is self locking aluminum with built-in gasketing.

  4. Aluminum & Steel Shelters Options

      Glazing: _" (6.4 mm) tempered safety glass, 0.1875" or 0.220" (4.8 or 5.6 mm) polycarbonate, tinting, in gray or bronze.

      Lighting: Twin bulb fluorescent fixtures.

      Venting: Switch operated wall fans.

      Benches: 6' (1828.8 mm), 8' (2438.4 mm) end 10' (3048 mm) pedestal mounted polyvinyl chloride (PVC) coated heavy duty steel. Installed directly to concrete pad with expansion anchors.

    TYPES
    Building standard style options include classic square corner, soft corner, “easy round" and “tru-view.”
    COLORS
    Quaker Bronze is standard. Rawhide, Slate Gray, Ascot White, Black, Forest Green available upon request.
    ELECTRICAL
    Electrical wiring is done according to National Electrical Code (NEC) Standards. Load center is a General Electric 125 Amp 120/240 volt unit with 4 to 8 open circuits. Wiring is within surface mounted electrical metallic conduit (EMT) and a ground-fault circuit-interrupter (GFCI) duplex receptacle with tester is provided. Lighting is twin fluorescent light with tube cover. Heating is wall mounted electric with fan forced operation, 1500w/5120 BTU and thermostat in an enamel coated 20 ga steel cabinet.

  5. Technical Data
    APPLICABLE STANDARDS
    American Society for Testing & Materials (ASTM) – ASTM A500 – Standard Specification for Cold-Formed Welded and Seamless Carbon Steel Structural Tubing in Rounds and Shapes
    APPROVALS
    Consult AustinMohawk and Company, Inc.
    PHYSICAL/CHEMICAL PROPERTIES
    Test reports are available upon request.
    FIRE RATING
    Fire resistance performance varies depending on construction type and options. Consult AustinMohawk and Company, Inc.
    SOUND RATING
    Consult AustinMohawk and Company, Inc. for acoustical performance.
  6. Installation
    PREPARATORY WORK
    Handle and store product according to AustinMohawk and Company, Inc. recommendations. Protect building and accessory components until ready for installation. It is recommended shop drawings be prepared showing layout, profiles and all product component, including anchorage, accessories, finish colors, patterns and textures. Verify that substrate conditions which have been previously installed by other contractors are acceptable for product installation in accordance with manufacturer's instructions.
    METHODS
    Install building structure true to line, level, plumb, rigid, and secure. Level base plates to true plane with full bearing to support structure, set in-place with anchor bolts as recommended by building manufacturer.
    Aluminum Shelter Anchoring
    Install shelter on concrete pad 4" (101.6 mm) minimum thickness and 12" (304.8 mm) minimum larger than shelter in both length and width. Anchor shelter to pad using aluminum “boots” and factory supplied expansion anchors.
    Steel Shelter Anchoring
    Install shelter on concrete pad 6" (152.4 mm) thickness and 18" (457.2 mm) minimum larger than shelter in both length and width. Anchor shelter to pad using height adjustable steel base plates and _" (12.7 mm) minimum expansion anchors.
    Cleaning
    Remove temporary coverings and protection of adjacent work areas. Repair or replace damaged installed products. Clean installed products in accordance with manufacturer's instructions prior to owner's acceptance. Remove construction debris from site.
    Complete installation recommendations are available from the manufacturer.
    PRECAUTIONS
    Protect installed product and finish surfaces from damage during construction.
    BUILDING CODES
    Current data on building code requirements and product compliance can be obtained from AustinMohawk and Company, Inc.'s technical support specialists. Installation must comply with the requirements of all applicable local, state and national code jurisdictions.

  7. Availability & Cost
    AVAILABILITY
    These buildings are available throughout North America. Contact manufacturer for information on lead times.
    COST
    Product and installation cost information can be obtained from AustinMohawk and Company, Inc.

  8. Warranty
    Contact manufacturer.

  9. Maintenance
    Contact manufacturer.

  10. Technical Services
    Service personnel offer design assistance and technical support. Structures are accompanied by a trained representative to advise on unloading and installation procedures. For technical assistance, contact AustinMohawk and Company, Inc.

  11. Filing Systems
  • Architects' First Source for Product
  • MANU-SPEC®
  • Sweet's Catalog Files
  • Additional product information is available from the manufacturer upon request.
Contact Us
Quote It Now
© 2004-2010 AustinMohawk Inc. | Utica, New York | 1(800)765-3110